Analysis of the active fire protection system at the head office of Perumda Air Minum Surya Sembada in Surabaya City

Breadcrumb

  • Home

Zerlinda Amelia Ariska Putri * and Endang Dwiyanti

Department of Occupational Safety and Health, Faculty of Public Health, Airlangga University, Surabaya, Indonesia.

Research Article

World Journal of Advanced Research and Reviews, 2025, 25(03), 732-739

Article DOI: 10.30574/wjarr.2025.25.3.0756

DOI url: https://doi.org/10.30574/wjarr.2025.25.3.0756

Received on 29 January 2025; revised on 06 March 2025; accepted on 08 March 2025

Regional drinking water companies are regionally owned business units engaged in the distribution of clean water for public needs. One of the potential hazards and risks that may occur in office buildings is fire. Operational disruptions caused by fires can have widespread impacts, including disturbances in the distribution of clean water to customers. Therefore, this study aims to evaluate the implementation of the active fire protection system at the Head Office of Perumda Air Minum Surya Sembada, Surabaya, as an effort toward fire prevention and mitigation. This research employs a qualitative method with a descriptive observational approach. The results indicate that the compliance level of fire detectors, based on SNI 03-3985-2000, is 83%, which is classified as good. The compliance level of fire alarms, based on SNI 03-3985-2000, is also 83%, which is classified as good. The compliance level of sprinkler systems, based on SNI 03-3989-2000, is 70%, which is classified as fairly good. The compliance level of fire extinguishers, based on the Ministry of Labour and Transmigration Regulation No. Per. 04/MEN/1980, is 75%, which is classified as fairly good. The compliance level of hydrants, based on SNI 03-1745-2000, is 89%, which is classified as good. Thus, the overall compliance level of the active fire protection system implementation at the Head Office of Perumda Air Minum Surya Sembada, Surabaya, is 80%, which falls into the "fairly good" category.

Active Fire Protection System; Fire Detector; Fire Alarm; Sprinkler; Fire Extinguisher; Hydrant

https://journalwjarr.com/sites/default/files/fulltext_pdf/WJARR-2025-0756.pdf

Preview Article PDF

Zerlinda Amelia Ariska Putri and Endang Dwiyanti. Analysis of the active fire protection system at the head office of Perumda Air Minum Surya Sembada in Surabaya City. World Journal of Advanced Research and Reviews, 2025, 25(03), 732-739. Article DOI: https://doi.org/10.30574/wjarr.2025.25.3.0756.

Copyright © 2025 Author(s) retain the copyright of this article. This article is published under the terms of the Creative Commons Attribution Liscense 4.0

Footer menu

  • Contact

Copyright © 2026 World Journal of Advanced Research and Reviews - All rights reserved

Developed & Designed by VS Infosolution